Peukert's Formula, T = C / In (or C = T * In
C is theoretical capacity (in Amp-Hours (AH), equal to actual capacity at one Amp)
I is current (in Amps)
T is time (in Hours)
n is the Peukert number


See the attached PDF for the corresponding Peukert number for each flooded model.